AMI-NGS
Automated NGS Library Prep Workstation
AMI-NGS is a sample preparation and PCR workstation, allowing for an optimized, precise, and efficient NGS workflow.
Description
AMI-NGS is a sample preparation and PCR workstation, allowing for an optimized, precise, and efficient NGS workflow. Featuring automated library preparation and pre-sequencing processes, it is compatible with current leading reagent systems, for seamless integration into any laboratory.
-
Liquid handling range
1μL - 800μL
-
Weight
Approx. 70kg
-
Disposable tip sensing
Confirmation of tip pick-up and tip ejection
-
Liquid level detection
Pressure based technology for non-conductive tips
-
No. of adjustable pipettes
4
-
Sample capacity
Up to 48 samples per run
-
Liquid handling range
1μL - 800μL
-
Weight
Approx. 70kg
-
Disposable tip sensing
Confirmation of tip pick-up and tip ejection
-
Liquid level detection
Pressure based technology for non-conductive tips
-
No. of adjustable pipettes
4
-
Sample capacity
Up to 48 samples per run
Key Features & Specifications
Specification Table
| PRODUCT DESCRIPTION | Automated NGS Library Preperation Workstation |
| SAMPLE CAPACITY | Up to 48 Samples per Run |
| NUMBER OF ADJUSTABLE PIPETTES | 4 |
| LIQUID LEVEL DETECTION | Pressure-Based Liquid Level Detection (pLLD) |
| PIPETTING RANGE | 0.5-800 µL |
| FREE DISPENSE | Down to 0.5 µL |
| RESOLUTION | 0.1 µL |
| PIPETTING MONITORING | Pressure-Monitored Pipetting (PMP) |
|
PIPETTE PERFORMANCE |
Tip Volume (µL) Pipetting Volume (µL) Precision (%CV)
10 0.5 <10.0 10 1.0 <5.0 10 5.0 <2.0 50 0.5 <10.0 50 1.0 <5.0 50 10.0 <2.0 200 10.0 <3.0 200 50.0 <2.0 200 100.0 <1.5 1000 10.0 <5.0 1000 100.0 <1.5 1000 500.0 <1.5 |
| PRESSURE MONITORED PIPETTING | Real-Time Quality Control of the Liquid Transfer Process, Detects Pipetting Faults like Clots and Air Aspiration |
| TIP COMPATIBILITY | 10, 50, 200, and 1000 µL (Disposable Tips with Filters) |
| DISPOSABLE TIP SENSING | Confirmation of Tip Pick-Up and Tip Ejection |
| NUMBER OF REMOVEABLE COOLERS | Up to 4 |
| COOLER TEMPERATURE RANGE | 4-75°C |
| COOLER TEMPERATURE ACCURACY | ±0.5°C |
| COOLER TEMPERATURE UNIFORMITY | ±0.5°C |
| MAXIMUM SHAKING SPEED | 1800 RPM |
| MAGNETIC RACK AVG. + MAGNETIC FLUX DENSITY | >2000 GS |
| ULTRAVIOLET LIGHT INTENSITY | >400 mW/m2 |
| OUTER DIMENSIONS | 86cm x 82cm x 77cm |
| WEIGHT | Approx. 70kg |
| TEST CONDITIONS | Pipetting Specifications Determined Gravimetrically Under Strictly Controlled Environmental Conditions.* |
*TEST TEMP. 22°C ±2°C, RELATIVE HUMIDITY 50% ±5%, | TEST LIQUID TEMP. WITHIN ±0.5°C OF ROOM TEMP.